Self-acting Differential PressureBypass Valve

Self-acting Differential PressureBypass Valve

  • Reliable Quality
  • Reasonable Price
  • Fast Delivery
  • Service Hotline: +86-21-33758111
    Next: None
    Product Details

    Technical Parameters

    Product model: 500X

    Nominal diameter: DN50~1000mm

    Nominal pressure: PN1.0~2.5MPa

    Applicable medium: water, oil, sea water, sewage

    Applicable temperature: 0~80℃

    Structure length standard: GB/T12221-2005

    Connection flange standard: GB/T9113

    Pressure temperature grade: GB/T12224-2005

    Test inspection standard: GB/T13927-2008


    Product overview

    The 500X pressure relief/pressure sustaining valve is composed of a main valve, a pressure relief/pressure sustaining pilot valve needle valve, a ball valve, a micro filter and a pressure gauge to form a hydraulic control takeover system. Using hydraulic automatic operation, it can be used as a pressure relief valve and a pressure sustaining valve. When used as a pressure relief valve, it can maintain the water supply pressure below the set safety value; when used as a pressure sustaining valve, it can maintain the upstream water pressure of the main valve above the set value and maintain the upstream water supply pressure of the main valve.


    Working principle

    1. As a pressure relief valve: when the pressure relief/pressure sustaining pilot valve is adjusted to the pressure relief state, the water flows to the outlet through the needle valve, the main valve control room, the ball valve A, the pressure relief/pressure sustaining pilot valve, and the ball valve B. The main valve is open. When the inlet pressure exceeds the safety value set by the pressure relief/pressure sustaining pilot valve, the pressure relief pilot valve will automatically open, and part of the water will be released through the ball valve C to relieve the pipeline pressure. When the pressure returns to a safe value, the pressure relief valve closes automatically. When used as a pressure relief valve, each ball valve is normally open.


    2. As a pressure sustaining valve: when the pressure relief/pressure sustaining pilot valve is adjusted to the pressure sustaining state, as long as the inlet water pressure of the main valve is lower than the set value of the pilot valve, the pilot valve will be closed. The main control room is boosted and the main valve is closed. When the upstream water supply pressure of the main valve exceeds the set pressure of the pilot valve, the pressure-sustaining pilot valve can be opened, the water in the control room is discharged to the outlet through the ball valve, the pressure-reducing main valve of the control room is opened, and the water supply starts, that is, the upstream water pressure is maintained. When used as a pressure sustaining valve, the ball valve C is normally closed or replaced with a plug.


    The main technical parameters

    Nominal pressure (Mpa)

    Shell test pressure (MPa)

    Sealing test pressure (MPa)

    Applicable media

    Medium temperature (℃)

    1.0

    1.5

    1.1

    Water

    0-80

    1.6

    2.4

    1.76

    2.5

    3.75

    2.75


    Main part material

    Part Name

    Part material

    Body Bonnet

    WCB

    Seat Disc

    Copper alloy

    Seal O-ring

    Nitrile rubber

    Stem

    2Cr13

    Spring

    50CrVA

    Needle valve

    Copper alloy

    Ball

    Copper alloy

    Pressure relief/pressure sustaining pilot valve

    Copper alloy

    Micro filter

    Stainless steel


    Connection size 

    DN

    20

    25

    32

    40

    50

    65

    80

    100

    125

    150

    200

    250

    300

    350

    400

    450

    L

    150

    160

    180

    200

    203

    216

    241

    292

    330

    356

    495

    622

    698

    787

    914

    978

    H1

    463

    463

    463

    516

    516

    520

    537

    596

    653

    709

    805

    855

    953

    990

    1030

    1030

    H

    557

    557

    557

    610

    610

    625

    642

    750

    808

    864

    1135

    1185

    1325

    1385

    1445

    1445